  smartpro 2.6kva 1920w line interactive sine wave ups, extended-run & snmpwebcard options, 2u rack/tower, lcd, usb, rs232,epo, 120v model number: SMART2600RM2U description tripp lite smartpro line interactive ups with enhanced lcd interface offers network-grade power protection for critical server, network and telecommunications equipment. line interactive uninterruptible power supply (ups) with built-in auto-voltage regulation (avr) actively corrects brownouts and overvoltages back to usable levels while maintaining a full battery charge in case of power failure. tripp lite's unique configuration excels in exceptionally poor-power environments with two separate levels of voltage boost to correct both slight undervoltages and severe brownout conditions. interactive lcd interface reports ups operating mode, detailed ups and site-power data, plus enables a variety of ups setup and configuration options. super-fast switchover from line to battery power occurs within milliseconds to maintain operation of connected equipment without interruption or reboot. 96% line-mode efficiency offers reduced heat emissions and operating costs. network management interfaces support communications via usb, rs-232 and optional snmpwebcard network interface. hid-compliant usb interface enables integration with built-in power management and auto shutdown features of windows and mac os x. network communications ports enable detailed monitoring of equipment load levels, self-test data and utility power conditions. includes poweralert monitoring software and complete cabling. switched output load banks enable scheduled and real-time remote reboot and load shedding of select outlets. emergency power off (epo) interface. lcd display panel easily rotates for viewing in rackmount or tower configurations. audible alarm with push-button momentary alarm-cancel and silent-mode configuration options. programmable self-test. field-replaceable, hot-swappable battery modules. features tripp lite SMART2600RM2U line interactive 2u rack/tower ups with 2600va / 2.6kva / 1920w capacity and extended runtime options line interactive ups with automatic voltage regulation (avr) corrects brownouts and overvoltages from 83 to 145v nema 5-20p input plug; 4 nema 5-15/20r, 4 5-15r and 1 l5-20r output receptacles, two independently switched output load banks maintains uninterrupted operation of connected networking equipment during blackouts, surges, brownouts and overvoltages high 96% efficiency rating in line-power mode offers reduced power consumption and btu emisssions internal batteries offer 12.9 minutes at 50% load (960w) and 4.6 minutes at 100% load (1920w) extended runtime is available with optional bp48v24-2u (limit 1), bp48v60rt-3u (multi-pack compatible) and bp48v27-2us (multi-pack compatible) external battery configurations require the use of tripp lite's external battery configuration software (see manual) hot-swappable, user-replaceable internal batteries and external battery packs can be replaced with no disruption to connected equipment highlights 2.6kva / 2600va / 1920w line interactive 2u rack/tower ups, sine wave output 120v output, corrects brownouts and overvoltages from 83v to 145v interactive lcd interface, 4 post compatible mounting accessories 96% line-mode efficiency, 2 switched load banks usb, rs232, epo and slot for snmpwebcard option 120v nema 5-20p input, 4 nema 5-15r, 4 nema 5-15/20r & 1 l5-20r outlets package includes SMART2600RM2U ups system poweralert software with usb, serial & epo cabling 4 post installation kit owner's manual 1 / 6
front panel lcd monitoring screen with mode and enter buttons reports operating mode with 5-bar battery charge graphic, plus 7 selectable screens of detailed ups and site power information lcd interface also supports a number of advanced user setup and operating preferences ships with 4 post rackmount installation hardware; optional 2postrmkitwm enables 2 post rackmount/wallmount installation; optional 2-9ustand enables tower placement built-in usb, rs-232 and optional snmpwebcard accessory monitoring options hid-compliant usb interface enables integration with built-in power management and auto shutdown features of windows and mac os x included poweralert ups monitoring software; built-in emergency power off (epo) interface with cable specifications output output volt amp capacity (va) 2600 output kva capacity (kva) 2.6 output watt capacity (watts) 1920 output kw capacity 1.92 nominal output voltage(s) supported 120v frequency compatibility 60 hz output voltage regulation (line mode) -14%, +6% output voltage regulation (battery mode) +/- 5% built-in ups output receptacles 4 5-15r outlet(s); 4 5-15/20r outlet(s); 1 l5-20r outlet(s) built-in controllable switched load banks two switchable single-outlet 5-15r load banks output circuit breaker 15a breaker protects 5-15r, 20a breaker protects 5-15/20r, l5-20r is unbreakered output ac waveform (ac mode) sine wave output ac waveform (battery mode) pure sine wave input rated input current (at maximum load) 16a nominal input voltage(s) supported 120v ac ups input connection type 5-20p ups input cord length (ft.) 10 ups input cord length (m) 3 recommended electrical service 20a 120v phase single-phase 2 / 6
battery full load runtime (minutes) 4.6 min. (1920w) half load runtime (minutes) 12.9 min. (960w) expandable battery runtime extended runtime supported via optional external battery packs external battery pack compatibility bp48v24-2u (limit 1); bp48v60rt-3u (multi-pack compatible); bp48v27-2us (multi-pack compatible) dc system voltage (vdc) 48 battery recharge rate (included batteries) less than 4.5 hours from 10% to 90% replacement battery cartridge (internal ups battery replacement) rbc94-2u battery access front panel battery access door battery replacement description hot-swappable, user replaceable batteries voltage regulation voltage regulation description automatic voltage regulation (avr) maintains line power operation with an input voltage range of 83 to 145 overvoltage correction input voltages between 127 and 147 are reduced by 12% undervoltage correction input voltages between 95 and 104 are boosted by 12% severe undervoltage correction input voltages between 83 and 94 are boosted by 24% leds alarms & switches front panel lcd display front panel lcd information and configuration screen offers detailed ups and site power status and operating data, plus configuration of voltage, operating mode, alarm function and a variety of additional options (see manual for detailed lcd configuration and monitoring options) alarms audible alarm indicates ups startup, power-failure, low-battery, overload, ups fault and remote shutdown conditions alarm cancel operation power-fail alarm can be temporarily silenced using alarm-cancel switch; silent mode alarm configuration option available switches 3 pushbutton switches control off / on power status, mode selection and mute / enter control functions surge / noise suppression ups ac suppression joule rating 570 ups ac suppression response time instantaneous emi / rfi ac noise suppression yes physical installation form factors supported with included accessories 4 post 19 inch rackmount included mounting accessory description adjustable mounting rail kit included 3 / 6
installation form factors supported with optional accessories 2 post rackmount (2postrmkitwm); wallmount (2postrmkitwm); tower (2-9ustand) primary form factor rackmount ups / power module dimensions in primary form factor (height x width x depth / inches) 3.46 x 17.32 x 19.46 ups / power module dimensions in primary form factor (height x width x depth / cm) 8.8 x 44 x 41.8 rack height 2u secondary form factor tower (requires 2-9ustand ) ups / power module weight (lbs) 64 ups / power module weight (kg) 29.1 ups shipping dimensions (height x width x depth / inches) 7.8 x 21.7 x 24.2 ups shipping dimensions (height x width x depth / cm) 19.8 x 55.1 x 61.5 shipping weight (lbs) 72 shipping weight (kg) 32.7 cooling method fan ups housing material steel environmental operating temperature range +32 to +104 degrees fahrenheit / 0 to +40 degrees celsius storage temperature range +5 to +122 degrees fahrenheit / -15 to +50 degrees celsius relative humidity 0 to 95%, non-condensing ac mode btu / hr. (full load) 250 ac mode efficiency rating (100% load) 96% communications communications interface usb (hid enabled); db9 serial; contact closure; epo (emergency power off); slot for snmp/web interface network monitoring port description supports detailed monitoring of ups and site power conditions poweralert software included communications cable usb and db9 cabling included watchdog compatibility supports watchdog application, os and hard-reboot restart options for remote applications line / battery transfer transfer time 5 milliseconds (line to battery mode); 1 millisecond (battery to line mode) 4 / 6
low voltage transfer to battery power (setpoint) 83 high voltage transfer to battery power (setpoint) 145 special features grounding lug back panel grounding lug cold start (startup in battery mode during a power failure) cold-start operation supported high availability ups features hot swappable batteries green & high efficiency features greater than 95% efficiency - green ups; individually controllable load banks certifications ups certifications tested to ul1778 (usa); tested to csa (canada); tested to nom (mexico); meets fcc part 15 category a (emi); rohs (restriction of hazardous substances) warranty product warranty period (worldwide) 2-year warranty, 3 year with registration. note: registration is required for 3-year warranty. connected equipment insurance (u.s., canada & puerto rico) $250,000 ultimate lifetime insurance related items optional products model number description qty. wext5-2200-3000 5-year extended warranty - for smart line-interactive and online tower or rack models, 2200-3000va or less 1 bp48v27-2us bp48v27-2us - 2u external 48v rack/tower battery pack for select tripp lite ups systems 1 bp48v24-2u bp48v242u - external battery pack for ups system 1 bp48v60rt-3u external battery pack and cable. 3u, expandable, blue 2-point connector 1 snmpwebcard for remote monitoring and control via snmp, web, or telnet. 1 envirosense monitors temperature, humidity and contact-closure inputs. (requires snmpwebcard or switched pdu.) 1 modbuscard for remote monitoring and control via modbus protocol 1 srswitch magnetic door switch kit for front and rear doors; requires envirosense 1 2-9ustand enables tower placement of rackmount ups systems 1 2postrmkitwm enables 2-post rackmount or wallmount installation of select rackmount ups systems 1 pdu1220 basic pdu / power distribution unit - safe, reliable power distribution for critical networking equipment 1 5 / 6
more information, including related products, owner's manuals, and additional technical specifications, can be found online at: http://www.tripplite.com/sku/SMART2600RM2U . ? 2014 tripp lite. all rights reserved. all trademarks are the sole property of their respective owners. tripp lite has a policy of continuous improvement. specifications are subject to change without notice. photos may differ slightly from final products. 6 / 6
mouser electronics authorized distributor click to view pricing, inventory, delivery & lifecycle information: tripp lite: ? SMART2600RM2U


▲Up To Search▲   

 
Price & Availability of SMART2600RM2U

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X